Lets go verify the static fan controls in the iDRAC Web UI or also you can run the SDR command via IPMI. ![]() Next command you can control the fan speeds with the proper hexadecimal value for the ending, as you see 0x2D =45% so you will need to figure out your speed you want the server to be statically at. This next step below, will enable the static fan control for the server with IPMI. If you want to verify the directory type in ” dir “.īelow is an example: ipmitool.exe -l lanplus 0.0.0.0 -U root -P Password raw 0x30 0x30 0x01 0x00 – Replace all required fields with your own information. You can clip it off using nail clippers and solder a loop of wire or a clipped leg from an LED in it's place and the fan will run at full speed (107CFM). The thermistor is extending off the main PCB of the fan itself (it's a little green blobby thing). Open Command Prompt and Change Directory to C:\Program Files (x86)\Dell\SysMgt\bmc The thermal control is integrated into the fan. Login into iDRAC web interface, Go to iDRAC Settings – > Network -> IMPI over LAN (Enable it) Ipmitool -I lanplus -H -U -P sdr list full Ipmitool -I lanplus -U -P raw 0x30 0x30 0x02 0xff 0x2D This will verify Servers SDR Ipmitool -I lanplus -H -U -P raw 0x30 0x 30 0x01 0x00 This sets the Fans to a Static Speed to 45% Replace with iDRAC admin password This Enables Static Fan Control